ABSTRACT
The construction of a 3-phase motor operation indicator exposes the techniques and skills employed in the construction of complex electrical circuit. The combination of contactors overload relay and other component to achieved the desired goal is diagrammatically and descriptively treated of practical knowledge
TABLE OF CONTENTS
Title page
Approval page
Dedication
Acknowledgement
Abstract
Table of contents
CHAPTER ONE
1.0Introduction
1.1Background
1.2Aim and objective
1.3The scope of the project
1.4Organization of the report
CHAPTER TWO
2.0Literature review
2.1Explanation of terms
CHAPTER THREE
3.0Description
3.1Some common fault causes and remedies in induction motor
3.2Wiring or connection diagram
3.3Inside views of the project
3.4Front and side view of the project
CHAPTER FOUR
4.0Construction
4.1Assembly and packaging
4.2Testing and results
4.3Application and marketability
CHAPTER FIVE
5.0Conclusion and recommendation
5.1Conclusion
5.2Recommendation
5.3References
Disclaimer: Note this academic material is intended as a guide for your academic research work. Do not copy word for word. Note: For Computer or Programming related works, some works might not contain source codes
CITE THIS WORK
(2013, 03). The Construction Of A 3-phase Motor Operation Indicator.. ProjectStoc.com. Retrieved 03, 2013, from https://projectstoc.com/read/1215/the-construction-of-a-3-phase-motor-operation-indicator
"The Construction Of A 3-phase Motor Operation Indicator." ProjectStoc.com. 03 2013. 2013. 03 2013 <https://projectstoc.com/read/1215/the-construction-of-a-3-phase-motor-operation-indicator>.
"The Construction Of A 3-phase Motor Operation Indicator.." ProjectStoc.com. ProjectStoc.com, 03 2013. Web. 03 2013. <https://projectstoc.com/read/1215/the-construction-of-a-3-phase-motor-operation-indicator>.
"The Construction Of A 3-phase Motor Operation Indicator.." ProjectStoc.com. 03, 2013. Accessed 03, 2013. https://projectstoc.com/read/1215/the-construction-of-a-3-phase-motor-operation-indicator.
- Related Works
- Design And Construction Of A Computer Based Control Of Electrical Appliances
- The Design And Construction Of An Inverter
- Design And Construction Of An Automatic Power Changeover Switch
- Construction Of Automatic Change Over With Generator Trip Off
- Construction Of A Battery Changer Using Silicon Controlled Regulator (scr)
- Construction Of 500w12vinverter Charger
- Study Of Power System Under Transient Condition
- Design And Construction Of Uninterruptible Power Supply
- Construction Of Power Outage Alarm
- Digital Frequency Counter