ABSTRACT
The two most common condenser tube problems faced by industrial users are internal tube fouling and tube failure. Fouling can have a major impact on the generating efficiency or the capacity of the condenser while the tube leaks or failure can seriously impact unit availability and reliability. Fundamental understanding of the root cause(s) of these issues and their alleviation is essential to resolving these problems and/or preventing their future occurrence.
TABLE OF CONTENTS
CONTENTS PAGES
Title page…………………………………………………………………………..i
Dedication…………………………………………………………………………ii
Acknowledgement………………………………………………………………...iii
Table of contents…………………………………………………………………..iv
Abstract……………………………………………………………………………vi
CHAPTER ONE
1.0 INTRODUCTION……………………………………………………………1
CHAPTER TWO
2.0 LITERATURE SURVEY (condensation in the olden days)………………………………3
2.1 Operation principle of a condenser………………………………………………………..5
2.2 Components of the condenser……………………………………………………………...6
CHAPTER THREE
3.0 Fouling in condenser and condenser tube failure……………………………………………11
3.1 categories of condenser tube failures………………………………………………………..11
3.2 Fouling………………………………………………………………………...13
3.3 Types of Fouling………………………………………………………………13
CHAPTER FOUR
4.0 Fouling Removal………………………………….........................................17
4.1 Fouling prevention…………………………………………………………..19
4.2 Condenser tube failure correction…………………………………………...20
4.3 Prevention and avoidance of condenser tube failure………………………..20
CHAPTER FIVE
5.0 Conclusion……………………………………………………………………21
5.1 Recommendation……………………………………………………………..21
REFERENCE……………………………………………………………………21
Disclaimer: Note this academic material is intended as a guide for your academic research work. Do not copy word for word. Note: For Computer or Programming related works, some works might not contain source codes
CITE THIS WORK
(2017, 02). A Proposed Design For The Correction Of Fouling In Condensers.. ProjectStoc.com. Retrieved 02, 2017, from https://projectstoc.com/read/8323/a-proposed-design-for-the-correction-of-fouling-in-condensers-9354
"A Proposed Design For The Correction Of Fouling In Condensers." ProjectStoc.com. 02 2017. 2017. 02 2017 <https://projectstoc.com/read/8323/a-proposed-design-for-the-correction-of-fouling-in-condensers-9354>.
"A Proposed Design For The Correction Of Fouling In Condensers.." ProjectStoc.com. ProjectStoc.com, 02 2017. Web. 02 2017. <https://projectstoc.com/read/8323/a-proposed-design-for-the-correction-of-fouling-in-condensers-9354>.
"A Proposed Design For The Correction Of Fouling In Condensers.." ProjectStoc.com. 02, 2017. Accessed 02, 2017. https://projectstoc.com/read/8323/a-proposed-design-for-the-correction-of-fouling-in-condensers-9354.
- Related Works
- Cryogenic Science And Engineering
- Repair And Refurbishing Of Pilot Plant Temperature Control Apparatus
- Utlilization Studies Of Enugu Coal
- A Comparative Enthalpy Approach For Co- And Counter Current Flow In Concentric Tube Heat Exchanger
- Construction Of Water Storage Tank (2000 Litres)
- The Effect Of Environment On Corrosion
- Desulphurisation Kerosene
- Absorption Of Palm Oil With Synthetic Adsorbent (coal)
- Formulation And Production Of Alcohol From Palm Wine.
- Refining Of Vegetable Oil With Enugu Coal