ABSTRACT
The two most common condenser tube problems faced by industrial users are internal tube fouling and tube failure. Fouling can have a major impact on the generating efficiency or the capacity of the condenser while the tube leaks or failure can seriously impact unit availability and reliability. Fundamental understanding of the root cause(s) of these issues and their alleviation is essential to resolving these problems and/or preventing their future occurrence.
TABLE OF CONTENTS
CONTENTS PAGES
Title page…………………………………………………………………………..i
Dedication…………………………………………………………………………ii
Acknowledgement………………………………………………………………...iii
Table of contents…………………………………………………………………..iv
Abstract……………………………………………………………………………vi
CHAPTER ONE
1.0 INTRODUCTION……………………………………………………………1
CHAPTER TWO
2.0 LITERATURE SURVEY (condensation in the olden days)………………………………3
2.1 Operation principle of a condenser………………………………………………………..5
2.2 Components of the condenser……………………………………………………………...6
CHAPTER THREE
3.0 Fouling in condenser and condenser tube failure……………………………………………11
3.1 categories of condenser tube failures………………………………………………………..11
3.2 Fouling………………………………………………………………………...13
3.3 Types of Fouling………………………………………………………………13
CHAPTER FOUR
4.0 Fouling Removal………………………………….........................................17
4.1 Fouling prevention…………………………………………………………..19
4.2 Condenser tube failure correction…………………………………………...20
4.3 Prevention and avoidance of condenser tube failure………………………..20
CHAPTER FIVE
5.0 Conclusion……………………………………………………………………21
5.1 Recommendation……………………………………………………………..21
REFERENCE……………………………………………………………………21
Disclaimer: Note this academic material is intended as a guide for your academic research work. Do not copy word for word. Note: For Computer or Programming related works, some works might not contain source codes
CITE THIS WORK
(2017, 02). A Proposed Design For The Correction Of Fouling In Condensers.. ProjectStoc.com. Retrieved 02, 2017, from https://projectstoc.com/read/8323/a-proposed-design-for-the-correction-of-fouling-in-condensers-9354
"A Proposed Design For The Correction Of Fouling In Condensers." ProjectStoc.com. 02 2017. 2017. 02 2017 <https://projectstoc.com/read/8323/a-proposed-design-for-the-correction-of-fouling-in-condensers-9354>.
"A Proposed Design For The Correction Of Fouling In Condensers.." ProjectStoc.com. ProjectStoc.com, 02 2017. Web. 02 2017. <https://projectstoc.com/read/8323/a-proposed-design-for-the-correction-of-fouling-in-condensers-9354>.
"A Proposed Design For The Correction Of Fouling In Condensers.." ProjectStoc.com. 02, 2017. Accessed 02, 2017. https://projectstoc.com/read/8323/a-proposed-design-for-the-correction-of-fouling-in-condensers-9354.
- Related Works
- Energy Processing And Utilization
- The Effect Of Liquid Floerate And Gas Flowrate On A Packed Absorption Tower And Repair Of Equipment
- Plant Design Of High Fructose Corn Syrup
- Design And Implementation Of A Window Based Front-desk Information System (a Case Study Of May Fresh Savings And Loan Limited Onitsha
- Assessment Of Carbon Monoxide (co) Level In Enugu Metropolis Monitoring Industrial And Residential Area
- Head Loses In Horizontal And Vertical Orificemeter A Comparative Evaluation And Analyses With Apllication Of Statistical Method Of Data Reliability
- The Construction Of Sieve Analysis Equipment
- Special Formulation Of Liquid Detergent For Car Wash
- A Comparative Enthalpy Approach For Co- And Counter Current Flow In Concentric Tube Heat Exchanger
- Production Of Plant Mirror Using Local Raw Material