The Effect Of Liquid Floerate And Gas Flowrate On A Packed Absorption Tower And Repair Of Equipment

ProjectStoc - 58 pages 7759 words 1411 views Project Diploma/Degree/Masters Level Chemical Engineering ₦3500 Naira ($9.21 USD)

This is a Premium work, paid access only

Register/Login to Access Full Work

ABSTRACT
The purpose of the project is to study the effect of liquid flow rate and gas flow rate on the pressure drop in a packed absorption tower and also to repair and restore the packed absorption tower to good working condition.

Trouble shooting revealed that the exit drain value was broken due to carelessness on the part of former user of the equipment.  We had to carry out glassblowing operations using borosilicate glass to construct another value.  Once this was done pressure build up within the tower was restored for absorption operation to take place.
A plot of log DO/H against log a superficial gas velocity gave 2.0774 2.3037 and 1.4940 respectively for slopes at varied superficial liquid velocity.

We concluded that increase in gas flow rate lead to increase in pressure drop since the graph obtained is linear.  There was a drop in slope from lower liquid rate to higher as operation neared flooding condition.  This means that industrially more cost is alluded to pumping operation to be successful. 
 
TABLE OF CONTENT
Title
Letter of transmittal
Approval page
Dedication
Acknowledgement
Abstract
Table of content

CHAPTER ONE
INTRODUCTION
1.2 Objectives of the project

CHAPTER TWO
2.0 Literature review
2.1 Pressure drop
2.3 Loading and flooding
2.4 Description of tower
2.7 packing characteristic 
2.7.3 Water pump operation
2.8 Design procedure of tower
2.8.2 Selection of solvent

CHAPTER THREE
3.0 Experiment procedure
3.1 Glass  blowing process and procedure
3.1.1 General physical properties of glass
3.1.2 General chemical properties of glass
3.2 Borosilicate glass properties
3.3 Construction of drain value 

CHAPRER FOUR
Data analysis
Discussion

CHAPETR FIVE
Conclusion
Recommendation 
References
Appendix 1: summary of calculation
Graph  11: plot of log DP/H vs log a 46
Appendix 111: cost of repairing equipment 49
Appendix 111: scale drawing of packing absorption tower.
 

Disclaimer: Note this academic material is intended as a guide for your academic research work. Do not copy word for word. Note: For Computer or Programming related works, some works might not contain source codes

CITE THIS WORK

(2014, 12). The Effect Of Liquid Floerate And Gas Flowrate On A Packed Absorption Tower And Repair Of Equipment.. ProjectStoc.com. Retrieved 12, 2014, from https://projectstoc.com/read/5526/the-effect-of-liquid-floerate-and-gas-flowrate-on-a-packed-absorption-tower-and-repair-of-equipment-4576
"The Effect Of Liquid Floerate And Gas Flowrate On A Packed Absorption Tower And Repair Of Equipment." ProjectStoc.com. 12 2014. 2014. 12 2014 <https://projectstoc.com/read/5526/the-effect-of-liquid-floerate-and-gas-flowrate-on-a-packed-absorption-tower-and-repair-of-equipment-4576>.
"The Effect Of Liquid Floerate And Gas Flowrate On A Packed Absorption Tower And Repair Of Equipment.." ProjectStoc.com. ProjectStoc.com, 12 2014. Web. 12 2014. <https://projectstoc.com/read/5526/the-effect-of-liquid-floerate-and-gas-flowrate-on-a-packed-absorption-tower-and-repair-of-equipment-4576>.
"The Effect Of Liquid Floerate And Gas Flowrate On A Packed Absorption Tower And Repair Of Equipment.." ProjectStoc.com. 12, 2014. Accessed 12, 2014. https://projectstoc.com/read/5526/the-effect-of-liquid-floerate-and-gas-flowrate-on-a-packed-absorption-tower-and-repair-of-equipment-4576.